Number of Controllable I/O Points 32 points (Input: 16, Output: 16), When expanded: Max. 384 points
Programming Method/Control Method Relay symbol / Cyclic operation
Program Memory Built-in flash ROM (no backup battery required)
Number of Instructions: Basic Instructions 120 types approx.
Number of Instructions: High-Level Instructions 270 types approx.
Program Capacity 24 k /32 k /40 k / 64 k steps Can be selected at system register No. 0 When the program capacity is changed, the number of words that can be used in the data register (DT) is also changed. Program capacity DT Number of word 24k steps 32k steps(initial value) 40k steps 64k steps 65,533 words 32,765 words(initial value) 24,573 words 12,285 words
24k steps 32k steps(initial value) 40k steps 64k steps 65,533 words 32,765 words(initial value) 24,573 words 12,285 words
Operation Speed Basic instruction (NOT: /) : 10 ns/step approx. (Up to 10 k steps) ,0.18 μs/step approx. (10 k steps and later) Basic instruction (ST) : 40 ns/step approx. (Up to 10 k steps) ,0.65 μs/step approx. (10 k steps and later) High-level instruction (FOMV) : 0.14 μs/step approx. (Up to 10 k steps) , 1.2 μs/step approx. (10 k steps and later)
Base Scan Time I/O Refresh And Base Time Control unit: 100 μs or less approx. and FP0 / FP0R expanshion unit refresh time (Note) Note : Refresh times for FP0 / FP0R expansion units 8 points unit : Number of units×0.8ms 16 points unit : Number of units×1.0ms 32 points unit : Number of units×1.3ms 64 points unit : Number of units×1.9ms
Operation Memory: Relay: External Input (X) 1, 760 points (X0 to X109F)(Note 1, 2) Note 1 : The number of points that can be used depends on the combination of hardware. Note 2 : Some specifications are compatible with FPΣ.
Operation Memory: Relay: External Output (Y) 1, 760 points (X0 to X109F)(Note 1, 2) Note 1 : The number of points that can be used depends on the combination of hardware. Note 2 : Some specifications are compatible with FPΣ.
Operation Memory: Relay: Internal Relay (R) 8,192 points (R0 to R511F) (Note 1) Note 1 : Some specifications are compatible with FPΣ.
Operation Memory: Relay: Special Internal Relay (R) 800 points (R9000 to R951F)
Operation Memory: Relay: Timer/Counter (T/C) 1,024 points (initial setting, timer: 1,008 points, counter: 16 points)(Note) Note : An auxiliary timer instruction (F137) can be used to add the number of points.
Operation Memory: Relay: Link Relay (L) 2,048 points (L0 to L127F)
Operation Memory: Memory Area: Data Register (DT) 12,285 words or 24,573 words or 32,765 words or 65,533 words(Note) Note : System register No. 0 (program capacity) can be configured to select the capacity of the data register (DT).
Operation Memory: Memory Area: Special Data Register (DT) 1,000 words (DT90000 to DT90999)(Note) Note : Some specifications are compatible with FPΣ.
Operation Memory: Memory Area: Link Data Register (LD) 256 words (LD0 to LD255)
Operation Memory: Memory Area: Index Register (A) 14 words (I0 to ID)
Differential Points Points for the program capacity
Number of Master Control Relay (MCR) 256 points
Number of Labels (JP and LOOP) 256 points
Number of Step Ladders 1,000 stages
Number of Subroutines 500 subroutines
Number of Interrupt Program 9 programs •Input: 8 programs (INT0 to INT7) •Periodic: 1 program (INT24)
Sampling Trace Available(Note) [Sampling by commands / Sampling at regular time intervals (For one sampling: 16 bits + 3 words), 1,000 samples] Note : Logging trace and sampling trace cannot be used at the same time.
Comment Storage I/O comments, remarks and block comments can be stored. (no backup battery required, 1 M byte)
PLC Link Function (Serial Communication) Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported)
Password Available (32 digits)
Program Upload Protection Available
Program Protect Function Available
Self-Diagnosis Function Watchdog timer, program syntax check, etc.
Program Edition During Run Available
SD Memory Card Function SD memory card project copy, SD memory card access instruction, Logging trace function (Note) Note : Logging trace and sampling trace cannot be used at the same time.
Memory Transfer Available [Built-in memory (ROM ⇔ RAM)]
High Speed Counter: Main Unit Input Single-phase 4 channels (Max. 100 kHz each input) or 2-phase 2 channels (Max. 50 kHz each input)(Note) Note : The specifications are based on the rated input voltage of 24 V DC at +25 ℃ +77 ℉ . The maximum operation frequency may be lower depending on the applied voltage, ambient temperature, and conditions of use. The maximum operation frequency varies depending on how the unit is used.
Pulse Output: Main Unit Output 4 channels (Max. 100 kHz each axis)(Note) Note : The specifications are based on the rated input voltage of 24 V DC at +25 ℃ +77 ℉ . The maximum operation frequency may be lower depending on the applied voltage, ambient temperature, and conditions of use. The maximum operation frequency varies depending on how the unit is used.
PWM Output: Main Unit Output 4 channels (1 Hz to 70 kHz: 1,000 resolution / 70.001 kHz to 100 kHz: 100 resolution(Note) Note : The specifications are based on the rated input voltage of 24 V DC at +25 ℃ +77 ℉ . The maximum operation frequency may be lower depending on the applied voltage, ambient temperature, and conditions of use. The maximum operation frequency varies depending on how the unit is used.
Pulse Catch Input Interrupt Input Total 8 points (with high speed counter)
Periodical Interrupt 0.1 ms to 30 sec.
Potentiometer (Volume) Input Not available
Real Time Clock Year (last two digits), month, day, hour (24-hour display), minute, second and day of week(Note 1, 2) Note 1 : Accuracy of the clock / calendar (within ± 90 seconds per month at +25 ℃ +77 ℉ ).If an error of the clock / calendar becomes a problem in the system, set an accurate time periodically. Note 2 : If the battery is not attached, calendar information is cleared when the power is turned off. It will be necessary to set the date when the power is turned on.
Memory Backup: Backup by Instruction P13 Data register: all area(Note) Note : Data can be rewritten up to 10,000 times. Hold / non-hold areas can be specified in the system registers.
Memory Backup: Auto-Backup at Power Failure Counter: 16 points Internal relay: 128 points Data register: 315 words Note : Data can be rewritten up to 10,000 times. Hold / non-hold areas can be specified in the system registers.
Battery backup (only when a battery is installed) Hold areas or non-hold areas can be specified by setting the system registers No.6 to No. 13. (It is also possible to make the setting for hold all points.)
Battery Life 5 years or more under a production condition (operates for 8 hours per day)
CE Marking Directive Compliance EMC Directive, RoHS Directive
Rated Voltage 24 V DC
Operating Voltage Range 20.4 to 28.8 V DC
Current Consumption 170 mA or less
Allowed Momentary Power Off Time 4 ms (at 20.4 V DC), 10 ms (24 V DC or higher)
Operating Temperature 0 to +55 ℃ +32 to +131 ℉ , At storage: -40 to +70 ℃ - 40 to +158 ℉
Operating Humidity 10 to 95 % RH (at +25 ℃ +77 ℉ , no dew condensation allowed), At storage: 10 to 95 % RH (at +25 ℃ +77 ℉ , no dew condensation allowed)
Withstand Voltage (Detection current: 5 mA) 500 V AC for 1 minute Input and output terminals ⇔ power and functional ground terminals Input terminals ⇔ Output terminals
Insulation Resistance (Test voltage: 500 V DC) 100 MΩ or more Input and output terminals ⇔ power and functional ground terminals Input terminals ⇔ Output terminals
Vibration Resistance 5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, for 10 times each in X, Y, and Z directions (1 octave/min.) (JIS B 3502, IEC 61131-2)
Shock Resistance 147 m/s2, 4 times each in X, Y, and Z directions (JIS B 3502, IEC 61131-2)
Noise Immunity 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator) (Power supply terminal)
Operating Environment Free from corrosive gasses and excessive dust
Overvoltage Class Category II
Pollution Level Pollution level 2
Net Weight 130 g approx.
Interface RS-232C, three-wire system, 1 channel (Not insulated)
Transmission Distance 15 m 49.213 ft
Configuration 1 : 1 communication
Communication Method Full duplex / Half-duplex system
Synchronous Method Start-stop synchronization system
Transmission Cable Multi-conductor shielded wire
d (Specified at the system registers) 1,200(Note), 2,400(Note), 4,800, 9,600, 19,200, 38,400, 57,600, 115,200, 230,400 bits/sec. Note : System register no. 415 cannot be used to set the baud rate to 1,200 bps. To set the baud rate to 1,200 bps, use the SYS1 instruction. If the baud rate of any of the COM ports is 2,400 bps or lower, F-ROM access will slow down. Example) F12(ICRD) instruction, P13(ICWT) instruction, etc.
Transmission Format: Data Length 7 bits / 8 bits
Transmission Format: Parity none / odd / even
Transmission Format: Stop Bit 1 bit / 2 bits
Transmission Format: Start Code with STX / without STX
Transmission Format: End Code CR / CR + LF / none / ETX / Time (0 to 100.00 ms)
Data Transmission Order Transmit from bit 0 in character units
Communication Mode MEWTOCOL-COM (Master / Slave) (Computer link) General-purpose communication PLC link MODBUS RTU (Master / Slave)
Remark The start and end codes can be used only for general-purpose serial communications. The unit No. (station number) can be selected at system register No. 410.
Communication Interface Ethernet 100BASE-TX / 10BASE-T
Communication Speed 100 Mbps, 10 Mbps auto negotiation function
Total Cable Length 100 m 328.084 ft (500 m 1640.420 ft when a repeater is used)
Ber Of Simultaneous Connections Max. 10 (system connection: 1, user connection: 9)
Communication Protocol (Communication Layer) TCP / IP, UDP
DNS Supports name servers
DHCP Automatic IP address acquisition
FTP server/Client File transmission, server function, No. of users:1 Client function, Data file transfer
SNTP Time adjustment function
General-Purpose Communication 4 kB / 1 connection (user connection: 1 to 9) (Note) Note : General-purpose communications can be up to 4 kB (reception) and up to 2 kB (transmission) per connection.
Dedicated Communication EtherNet/IP MEWTOCOL-COM (Master / Slave) (Computer link) MODBUS-TCP (Master / Slave) MEWTOCOL-DAT (Master / Slave) General-purpose communication MC protocol (Note 1) (Master / Slave) Note : MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation.QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
Standard USB2.0 Full speed (USB mini B type)
Communication Function Computer link (slave)
:5V Connecting programmable display model : For 5 V DC type GT02 series Programmable Display
Rated Input Voltage 24 V DC
Applied Voltage Range 21.6 to 26.4 V DC
Rated Input Current High-speed part (X0 to X7) : 8 mA approx. Low-speed part (X8 to XF) : 3.5 mA approx.
Output Points Per Common 16 points/common (Y0 to YF / 1 common)
Min. On Voltage/Min. On Current High-speed part (X0 to X7) : 19.2 V DC / 6 mA Low-speed part (X8 to XF) : 19.2 V DC / 3 mA
Max. Off Voltage/Max. Off Current 2.4 V DC / 1 mA
Input Impedance High-speed part (X0 to X7) : 3 kΩ approx. Low-speed part (X8 to XF) : 6.8 kΩ approx.
Response Time: OFF→ON High-speed part (For Y0, Y1, Y3, Y4, Y8, Y9, YB, YC) : 2 μs or less, Low-speed part (For Y2, Y5, Y6, Y7, YA, YD, YE, YF) : 1 ms or less
Response Time: ON→OFF High-speed part (For Y0, Y1, Y3, Y4, Y8, Y9, YB, YC) : 5 μs or less, Low-speed part (For Y2, Y5, Y6, Y7, YA, YD, YE, YF) : 1 ms or less
Action Indicator LED display
Output Type Pch open drain
Rated Load Voltage 24 V DC
Load Voltage Allowable Range 21.6 to 26.4 V DC
Rated Load Current 0.3 A (For Y0 to YF)
Max. Surge Current High-speed part (For Y0, Y1, Y3, Y4, Y8, Y9, YB, YC) : 1.0 A, Low-speed part (For Y2, Y5, Y6, Y7, YA, YD, YE, YF) : 0.5 A
FF State Leakage Current 2 μA or less
N State Voltage Drop 0.5 V DC or less
Overcurrent Protection Provided (automatically protected for each 8 points)
Surge Absorber Zener diode
Rating Mode Indicator LED display

Last 6 months Inventory & Pricing History


Alternative Descriptions

Automation module: PLC programmable controller | TME
PLC, 16 IN 16 OUT, ETHERNET RS232C, FP0H SERIES | RS Americas
Fp0H Cpu: 16 16 Pnp, 4 Axis 100Khz, Ethernet/Ip, Sd, rs232, Usb |Panasonic AFP0HC32EP | Newark Electronics


Frequently Asked Questions

Where can I find additional details, specifications and documents for a AFP0HC32EP?

Additional datasheets, footprints and schematics for AFP0HC32EP are listed on our Part Details page. You can also find images and similar parts to AFP0HC32EP on this page.

What pricing and inventory information can I view?

Distributor pricing and stock information is available for AFP0HC32EP on our Product Comparison page. Access via the 'View Pricing & Stock' button to view AFP0HC32EP price breaks, MOQs, lead times, inventory and SKUs from distributors.

What category does AFP0HC32EP fall under?

The AFP0HC32EP is listed under Industrial Automation > PLC & HMI > Programmable Logic Controllers / Interface Terminal > FP0H Series.

Can I view similar or alternative parts?

You can view similar parts to AFP0HC32EP when available in the FP0H Series range under the specifications section at the bottom of the details page.

Who can I contact for technical support of the product?

Submit any questions directly to the customer support team of the distributor listing the product. For the AFP0HC32EP you can contact the distributor directly for product support, shipping queries etc.

Is the AFP0HC32EP RoHS compliant?

This part has not been flagged as RoHS Compliant.

Which authorised distributors for AFP0HC32EP have stock available?

Authorised distributors including Ozdisan, TME, RS Americas and Newark Electronics have stock available or on a lead time for AFP0HC32EP.

How do I check stock and lead times for all distributors?

Stock availability and lead times will be displayed for AFP0HC32EP often in real-time on the comparison pages.

What if I can't find stock of AFP0HC32EP?

You can fill out our help required form which you can use to request a quote for AFP0HC32EP from some of our verified obsolescence suppliers. Alternatively, contact us via our web chat in the bottom left of your screen and one of our team will try to help.