| Status: | Unknown |
|---|---|
| Series: | - |
| RoHS: | Unknown |
| CE Marking Directive Compliance | EMC Directive, RoHS Directive |
|---|---|
| Rated Pressure Range | DPH-L113V : -0.1 to +1 MPa DPH-L113 : 0 to +1 MPa DPH-L133 : 0 to +3.5 MPa DPH-L114 : 0 to +10 MPa DPH-L154 : 0 to +50 MPa (Note) : Values differ depending on a connected sensor head. |
| Set Pressure Range | [DPH-L113V] -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm2 -11.77 to +11.77 bar -170.6 to +170.6 psi [DPH-L113] -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm2 -10.70 to +10.70 bar -155.2 to +155.2 psi [DPH-L133] -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm2 -37.4 to +37.4 bar -542 to +542 psi [DPH-L114] -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm2 -107.0 to +107.0 bar -1552 to +1552 psi [DPH-L154] -53.5 to +53.5 MPa -545 to +545 kgf/cm2 -535 to +535 bar -1980 to +7760 psi (Note) : Values differ depending on a connected sensor head. |
| Set Pressure Resolution | DPH-L113V : 0.001 MPa DPH-L113 : 0.001 MPa DPH-L133 : 0.01 MPa DPH-L114 : 0.01 MPa DPH-L154 : 0.1 MPa (Note): Values differ depending on a connected sensor head. |
| Display | 4 digits +4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Display: Displayable Pressure Range | [DPH-L113V] -0.155 to +1.022 MPa -1.58 to +10.42 kgf/cm2 -1.55 to +10.22 bar -22.4 to +148.2 psi [DPH-L113] -0.050 to +1.020 MPa -0.51 to +10.40 kgf/cm2 -0.50 to +10.20 bar -7.2 to +148.0 psi [DPH-L133] -0.17 to +3.57 MPa -1.7 to +36.4 kgf/cm2 -1.7 to +35.7 bar -24 to +518 psi [DPH-L114] -0.50 to +10.20 MPa -5.1 to +104.0 kgf/cm2 -5.0 to +102.0 bar -72 to +1480 psi [DPH-L154] -2.5 to +51.0 MPa -25 to +520 kgf/cm2 -25 to +510 bar -360 to +7400 psi (Note): Values differ depending on a connected sensor head. |
| Supply Voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Power Consumption | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
| Comparative Output | PNP open-collector transistor (2 outputs) Maximum source current : 50 mA Applied voltage : 30 V DC or less (between comparative output and +V) Residual voltage : 1 V or less (at 50 mA source current) |
| Comparative Output: Output Operation | NO / NC, selectable by key operation |
| Comparative Output: Output Modes | EASY mode / Hysteresis mode / Window comparator mode |
| Comparative Output: Hysteresis | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
| Comparative Output: Repeatability | Within ±0.2 % F.S. |
| Comparative Output: Response Time | 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Comparative Output: Short-Circuit Protection | Incorporated |
| Analog Output | Output current : 1 to 5 V DC Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V) Span : within 4 V ±0.5 % F.S. Linearity : within ±0.1 % F.S. Output impedance : 1 kΩ approx. Output current : 4 to 20 mA Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V) Span : within 16 mA ±1.5 % F.S. Linearity : within ±0.1 % F.S. Load resistance : 250 Ω (max.) |
| Inputs: Sensor Head Input | Input voltage range : 1 to 5 V DC (over rated pressure range) |
| Inputs: External Input | ON voltage : 5 V to +V DC OFF voltage : 0.6 V DC or less, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more |
| Operation Indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON ) |
| Protection | IP40 (IEC) |
| Ambient Temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ |
| Ambient Humidity | 35 to 85 % RH, Storage : 35 to 85 % RH |
| Voltage Withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure |
| Insulation Resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Vibration Resistance | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Shock Resistance | 100 m/s2 acceleration in X, Y and Z directions three times each |
| Temperature Characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉ ) |
| Material | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber |
| Connecting Method | Connector |
| Cable Length | Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. |
| Weight (Typ.) | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. |
| Accessories | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set |
| Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉ . The values specified above are applied only to the controller. |
| DIGITAL CONTROLLER FOR DPH-L, PNP WITH 2M CABLE | RS Americas |
Where can I find additional details, specifications and documents for a DPC-L101-P?
Additional datasheets, footprints and schematics for DPC-L101-P are listed on our Part Details page. You can also find images and similar parts to DPC-L101-P on this page.
What pricing and inventory information can I view?
Distributor pricing and stock information is available for DPC-L101-P on our Product Comparison page. Access via the 'View Pricing & Stock' button to view DPC-L101-P price breaks, MOQs, lead times, inventory and SKUs from distributors.
What category does DPC-L101-P fall under?
The DPC-L101-P is listed under Industrial Automation > Industrial Sensors > Pressure Sensors / Flow Sensors > Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100.
Can I view similar or alternative parts?
You can view similar parts to DPC-L101-P when available in the Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100 range under the specifications section at the bottom of the details page.
Who can I contact for technical support of the product?
Submit any questions directly to the customer support team of the distributor listing the product. For the DPC-L101-P you can contact the distributor directly for product support, shipping queries etc.
Is the DPC-L101-P RoHS compliant?
This part has not been flagged as RoHS Compliant.
Which authorised distributors for DPC-L101-P have stock available?
Authorised distributors including RS Americas have stock available or on a lead time for DPC-L101-P.
How do I check stock and lead times for all distributors?
Stock availability and lead times will be displayed for DPC-L101-P often in real-time on the comparison pages.
What if I can't find stock of DPC-L101-P?
You can fill out our help required form which you can use to request a quote for DPC-L101-P from some of our verified obsolescence suppliers. Alternatively, contact us via our web chat in the bottom left of your screen and one of our team will try to help.